| Details | - The MEC II-series pumps have an automatic protection system. So, for example, if a vane breaks, the rotor and rotor housing can be protected by the rotor—including the flange mountings—being pushed downwards
- Pumps with a "ballast system", identified by B at the end of the item number (e.g. MEC9000MB) have a longer operating time in vacuum operation
- The operating time at -0.95 bar lasts from 8 minutes (standard) up to a maximum of 15 minutes. Continuous operation is permissible at -0.6 bar.
- MEC II-series pumps are supplied with long-life (heat-resistant) vanes as standard
- MEC II-series pumps feature a temperature meter to enable the temperature to be read during operation
- A maintenance hatch can be used to determine the wear condition of the vanes, indicating when the vanes need to be replaced
- Each pump is subjected to a final check in the factory, in which the vacuum, compression and lubrication are tested, among other factors
- A test report relating to the serial number is drawn up for each pump
| |
|---|
| Detalii produs | - Costuri minime de reparații datorită sistemului unic de protecție automată
- Deoarece pompele de la B.P. sunt testate, inspectate și ambalate cu cea mai mare atenție, pornirea fără probleme este garantată 100%.
- Aceste pompe vacuum cu palete sunt utilizate în principal în agricultură, pentru umplerea și golirea rezervoarelor de nămol
- Aceste pompe pot genera atât presiune pozitivă, cât și vid
- Fără supapă de suprapresiune (articol 0200013) și supapă de vid (articol 0155513)
- Fără motor hidraulic și bucșă
- Pompele se livrează fără ulei de lubrifiere (articol BP5070).
- Inclusiv baza hidraulică pentru montarea motorului hidraulic.
| |
|---|
| Informaţii tehnice | - Composition of the item numbers: MEC = series, 9000 = type, H = hydraulic drive, B = ballast system
- On pumps without automatic lubrication (no "A" in the item number), the pump is equipped with a forced lubrication system that is adjusted using dripper nozzles Automatic lubrication available on request
- On pumps without automatic lubrication, the quantity of lubrication oil is set in the factory and cannot be changed without a tool
- In the case of forced lubrication, as with automatic lubrication, the function must be checked at all times during operation
- Pumps with hydraulic drive are clockwise
- The direction of rotation is determined when the axle to be driven is aligned with the observer
- Oil to be used for lubricating the vanes: genuine oil from B. P. (item number BP5070)
| |
|---|