| Long description | Equalising valves or brake valves provide controlled movement, stopping and holding of loads. They prevent the lag of movements (negative load) and protect the installation against external forces (anti-shock). Overcentre valves provide controlled initiation and stopping of a movement, while holding the load at rest. When mounted directly on the cylinder or motor, they also function as hose breakage protection. | |
|---|
| Pros | - Allows smooth, controlled movements and accurate positioning of pulling and pushing loads
- Hose breakage protection if fitted as close to the user as possible
- Negative final check
| |
|---|
| Product details | - Load-holding function adjustable for A or B lines, pressure setting should be approx. 30% higher than the maximum load pressure
- Operation is return pressure dependent, high return pressure may adversely affect the function of the valve
- Free flow from V to C
- Max. pressure 350 bar.
- Max. flow Range 0 to 120 l/min
| |
|---|
| Application range | - Lasthaltung, Bewegungskontrolle
- z.B. Teleskoplader, Frontlader,Krananwendungen, Gabelstapler
| |
|---|
| Properties | - Maximaler Betriebsdruck 350 Bar
- Einstellbare Lasthalte- und Gegenhaltefunktionen für A und B Leitung
- Ermöglicht weiche, kontrollierte Bewegungen und genaue Positinierung von ziehenden und schiebenden Lasten
- Funktion als Leitungsbruchsicherung
- Schutz vor Druckspitzen durch externe Kräfte
| |
|---|
| Technical info | - Am Steuerventil müssen die Anschlüsse A,B und T in der Neutralstellung miteinander verbunden sein
- Druckeinstellung muss ca. 30% höher als der maximale Lastdruck sein
- Öffnungsdruck ist abhängig von Druckeinstellung, Lastdruck und Steuerdruckverhältnis
| |
|---|
| Includes | | |
|---|